Publications
Department of Medicine faculty members published more than 3,000 peer-reviewed articles in 2022.
2013
2013
2013
2013
BACKGROUND
Cleft lip, with or without cleft palate (CL±P), is the most common craniofacial anomaly in newborns. The incidence of CL±P varies among different ethnic populations and is presumed to be higher in developing countries. In the Middle East, the incidence has variably been reported as 0.3 to 2.19 per 1000 live births and is generally regarded as similar to Caucasians. There is currently no literature reporting the incidence of clefting in Palestinians living in the territories. Reports from Palestinian populations in Israel and Jordan infer an incidence of 1.39 per 1000 live births. However, the reported incidence in stable populations may not reflect the actual incidence of clefting in the territories.
METHODS
This is a retrospective study examining all newborn records at Makassed Maternity Hospital in Jerusalem between January 1, 1986, and December 12, 1995. Data were collected by the senior author (A.D.) and interpreted by coauthors. Frequencies were established based on the number of isolated and nonisolated CL±P born during this time period.
RESULTS
During the 10-year period from January 1, 1986, to December 12, 1995, there were 33,239 live births. Among these births, there were 35 isolated and nonisolated combined CL±P born (1.05/1000 live births).
CONCLUSIONS
Based on this limited data set from a single, tertiary referral hospital, we conclude that the prevalence rate of CL±P among a Palestinian population may be less than that reported in surrounding areas. However, more broadly based studies using nationalized birth registries are required to determine an accurate prevalence rate of CL±P among Palestinians.
View on PubMed2013
OBJECTIVES
The purpose of this study was to investigate the associations of traditional risk factors and longitudinal measures of human immunodeficiency virus (HIV) disease severity with risk of incident atrial fibrillation (AF) in a contemporary cohort of HIV-infected individuals.
BACKGROUND
Cardiovascular disease is common in HIV-infected persons; however, the most common cardiac arrhythmia, AF, has not been adequately studied in this population.
METHODS
We studied a national sample of 30,533 HIV-infected veterans followed in the Veterans Affairs HIV Clinical Case Registry from 1996 to 2011. We examined the independent associations of demographic characteristics, time-updated comorbidities, and time-updated clinical measurements including CD4(+) cell count and viral load with the outcome of incident AF using proportional hazards regression for multivariable analysis.
RESULTS
Over a median follow-up of 6.8 years, 780 (2.6%) patients developed AF. After multivariable adjustment for traditional risk factors, a lower CD4(+) cell count (<200 compared with >350 cells/mm(3); hazard ratio [HR]: 1.4; 95% confidence interval [CI]: 1.1 to 1.8; p = 0.018) and higher viral load (>100,000 compared with <500 copies/ml; HR: 1.7; 95% CI: 1.2 to 2.4; p = 0.002) were independently associated with increased risk of incident AF. Additional risk factors independently associated with risk of AF included older age, White race, coronary artery disease, congestive heart failure, alcoholism, proteinuria, reduced kidney function, and hypothyroidism.
CONCLUSIONS
In a large HIV-infected cohort, markers of HIV disease severity represented by low CD4(+) cell count and high viral load, assessed by multiple time-updated measures, were independently associated with development of AF.
View on PubMed2013
Access to sputum smear microscopy in high-tuberculosis (TB)-burden regions is limited by a scarcity of microscopes and experienced technicians. We evaluated the accuracy of CellScope, a novel digital fluorescence microscope that may expand access to microscopy. The study utilized smear microscopy slides prepared from sputum specimens submitted by consecutive adults with ≥ 2 weeks of cough who were admitted to Mulago Hospital (Kampala, Uganda). Conventional light-emitting diode (LED) fluorescence microscopy (FM) and mycobacterial culture were performed by experienced technicians. Two U.S.-based postgraduate researchers without prior microscopy experience restained, imaged, and interpreted the slides using CellScope. We assessed whether sensitivity and specificity of CellScope-based LED FM was noninferior to conventional LED FM by using a preselected margin of inferiority of 15%. Of 525 patients included, 72% were HIV seropositive and 39% had culture-confirmed TB. The proportions of positive results were similar with CellScope and conventional LED FM (34% versus 32%, respectively; P = 0.32), and agreement was substantial. CellScope accuracy was within the noninferiority margin for both sensitivity (63% versus 70%; difference, -7%; 95% confidence interval [CI], -13% to -1%) and specificity (85% versus 92%; difference, -7%; 95% CI, -12% to -3%). A subanalysis of 43 slides evaluated by each CellScope reader found substantial interreader reliability (custom-weighted kappa, 0.65) and variable intrareader reliability (custom-weighted kappa, 0.11 versus 0.48). CellScope offers promise for expanding microscopy services. Future studies should evaluate the device when operated by health workers in low-resource settings, the feasibility of image transmission and analysis by experienced microscopists, and the accuracy of automated image analysis algorithms.
View on PubMed2013
The purpose of this study was to describe application and machine accuracy for a new computed tomography (CT) guided, frameless, stereotactic brain biopsy system in dogs. Heads from ten canine cadavers were secured to a bite-plate with six attached fiducial markers and imaged using CT. Fiducialized CT images were imported into stereotactic software and spherical phantom lesions between 3.9 and 5.5 mm in diameter were created in six locations. Infrared cameras and reflective markers were used to register fiducials to the reconstructed image set. Coordinates in the X, Y, and Z planes were identified for each lesion center. Iohexol (1.5 μl of 240 mgI/ml) was injected into the center of each lesion and CT scans were repeated. Pre- and postinjection CT images for each cadaver were fused using the system software. Application accuracy was calculated using the center of each phantom lesion and the center of each injected contrast material location. Machine accuracy was calculated using a phantom with known distances between four fixed points in the X, Y, and Z planes. Mean application accuracy in the first 5 cadavers was 4.3 mm (95% confidence interval [CI] 2.9-4.3 mm) and in the second 5 cadavers was 2.9 mm (95% CI 2-3.9 mm). The more superficial lesions were targeted significantly less accurately than the deeper lesions (P = 0.0183). Median machine accuracy was 0.1 mm and the range was 0.1-0.2 mm. Findings supported use of the new biopsy system for canine brain lesions >3.9 mm in diameter.
View on PubMed2013