BACKGROUND
Prior studies have indicated that the magnitude of risk association of microvolt T-wave alternans (MTWA) testing appears to vary with the population studied. We performed a meta-analysis to determine the ability of MTWA to modify risk assessment of ventricular tachyarrhythmic events (VTEs) and sudden cardiac death (SCD) across a series of patient risk profiles using likelihood ratio (LR) testing, a measure of test performance independent of disease prevalence.
METHODS
We identified original research articles published from January 1990 to January 2011 that investigate spectrally derived MTWA. Ventricular tachyarrhythmic event was defined as the total and arrhythmic mortality and nonfatal sustained or implantable cardioverter-defibrillator-treated ventricular tachyarrhythmias. Summary estimates were created for positive and nonnegative MTWA results using a random-effects model and were expressed as positive (LR+) and negative (LR-) LRs.
RESULTS
Of 1,534 articles, 20 prospective cohort studies met our inclusion criteria, consisting of 5,945 subjects predominantly with prior myocardial infarction or left ventricular dysfunction. Although there was a modest association between positive MTWA and VTE (relative risk 2.45, 1.58-3.79) and nonnegative MTWA and VTE (3.68, 2.23-6.07), test performance was poor (positive MTWA: LR+ 1.78, LR- 0.43; nonnegative MTWA: LR+ 1.38, LR- 0.56). Subgroup analyses of subjects classified as prior VTE, post-myocardial infarction, SCD-HeFT type, and MADIT-II type had a similar poor test performance. A negative MTWA result would decrease the annualized risk of VTE from 8.85% to 6.37% in MADIT-II-type patients and from 5.91% to 2.60% in SCD-HeFT-type patients.
CONCLUSIONS
Despite a modest association, results of spectrally derived MTWA testing do not sufficiently modify the risk of VTE to change clinical decisions.
View on PubMed2012
2012
BACKGROUND
Tandem colonoscopy is regarded as the reference standard for the evaluation of the adenoma detection rate (ADR) and adenoma miss rate (AMR) during colonoscopy. Pooled results from previous tandem studies yield AMRs of 22%. The AMR of trainees is important to estimate the number of colonoscopies required to develop competence in screening for colorectal neoplasms.
OBJECTIVE
To measure the ADR and AMR of trainees as a function of experience.
METHODS
Prospective tandem colonoscopy study at an academic VA medical center. A trainee initially attempted colonoscopy. If the trainee was able to intubate the cecum, the trainee performed the withdrawal, and the colonoscopy was then repeated by the attending physician to assess the AMR.
RESULTS
Twelve trainee endoscopists were included in the study. Trainees had between 0 and 33 months of previous endoscopic experience and had done between 0 and 605 previous colonoscopies. A total of 230 patients were evaluated for the study, and 218 patients were enrolled. Complete tandem colonoscopy was performed in 147 patients. There was a 54% ADR. The mean (standard deviation) size of the adenomas in the cohort was 5.9 (5.3) mm. Significant variables in multivariate logistic regression analysis for missed adenomas were trainee experience (P = .011) and patient age (P < .001). The AMR decreased with increasing experience, and it is estimated that 450 colonoscopies are required to attain AMRs of less than 25% in a 60-year-old patient.
LIMITATIONS
Single-center study; the attending physician performing the second pass was not blinded to the first pass. The AMR was only analyzed for cases in which the trainee was able to reach the cecum with no or minimal assistance.
CONCLUSIONS
Our tandem colonoscopy study demonstrates that the AMR decreases as the experience of trainees increases and is a late competency attained during training. Future training may need to incorporate these findings to serve as a basis for determining appropriate training guidelines.
View on PubMed